CURRENT TRANSFORMER UP TO 3.3 kV. |
|
Guide of selection up to 3.3 kV. |
|
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer. |
|
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities. |
|
Current transformers Indoors Type up to 3,3kV. |
Application Range(Amp) |
Power until (V.A) |
Class |
Security factor limit |
Model |
Data |
5-5000 |
Under order |
MTE |
|
5-10 á 400-800 |
15/30 |
0.5/5p |
5/10 |
MT1S |
|
500 - 4000 |
30 |
0.5 |
5 |
MP4 Normalized interior diameter. |
|
MP4 Special interior diameter. |
|
500 - 4000 |
30/30 |
0.5/10p |
5/10 |
MP4-R |
|
|
|
NOTE: This selection is valid also for secondary of measurement in Class 0,5s.. |
|
NOTE II: The transforming can offer with bases without projections also respecting the measures limited in the planes. |
|
|
|
|
CURRENT TRANSFORMER UP TO 13.2 kV. |
|
Guide of selection up to 13,2 kV. |
|
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer. |
|
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities. |
|
Current transformers Indoors Type up to 13,2kV. |
Application Range(Amp) |
Power until (V.A) |
Class |
Security factor limit |
Model |
Data |
5-10 á 300-600 |
30 |
0.5 |
5 |
MJ7 |
|
5-10 á 300-600 |
30/30 |
0.5/10p |
5/10 |
MJ8 Secondary double, primary lineal. |
|
MJ8 Secondary double, primary rhombus. |
|
5-10 á 400-800 |
30/60 |
0.5/10p |
5/10 |
MJ14 Secondary triple, primary lineal. |
|
MJ14 Secondary triple, primary rhombus. |
|
5-10 á 400-800 |
30/30/60 |
0.5/10p/10p |
5/10/10 |
MJ14 Secondary triple, one independent. |
|
MJ14 Secondary double. |
|
MJ14 Secondary double, primary in rhombus. |
|
500 á 4000 |
15/30/30
|
0.5/10p10p
|
5/10/10
|
MJ17 Length 390 mm. |
|
MJ17 Length 440 mm. |
|
5-10 á 600-1200 |
15/30 |
0.5/10p |
5/10 |
ABK-10 |
|
1500 á 3000 |
15/30 |
0.5/10p |
5/10 |
ABK-10 |
|
5-10 á 600-1200 |
30/60 |
0.5/10p |
5/10 |
ABK-20R |
|
1500 á 3000 |
30/60 |
0.5/10p |
5/10 |
ABK-20R |
|
5-10 á 600-1200 |
30/30/30 |
0.5/10p/10p |
5/10/10 |
ABK-20E |
|
1500 á 3000 |
30/30/30 |
0.5/10p/10p |
5/10/10 |
ABK-20E |
|
|
|
|
NOTE: This selection is valid also for secondary of measurement in Class 0,5s.. |
|
NOTE II: The transforming can offer with bases without projections also respecting the measures limited in the planes. |
|
|
|
|
CURRENT TRANSFORMER UP TO 33 kV. |
|
Guide of selection up to 33 kV. |
|
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer. |
|
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities. |
|
Current transformers Indoors Type up to 33kV. |
Application Range(Amp) |
Power until (V.A) |
Class |
Security factor limit |
Model |
Data |
5-10 á 300-600 |
30/30 |
0.5/10p |
5/10 |
MJ35 Primary in Rhombus. |
View Details |
5-10 á 400-800 |
30/60 |
0.5/10p |
5/10 |
MJ35 Primary Lineal. |
|
MJ35 Primary in Rhombus. |
|
5-10 á 400-800 |
30/30/60 |
0.5/10p/10p |
5/10/10 |
MJ35 Primary Lineal. |
|
MJ35 Primary in Rhombus. |
|
5-10 á 600-1200 |
30/30/30 |
0.5/10p/10p |
5/10/10 |
ABK35 |
|
1500 á 3000 |
30/30/30 |
0.5/10p/10P |
5/10/10 |
ABK35 |
|
|
|
NOTE: This selection is valid also for secondary of measurement in Class 0,5s.. |
|
|
|
|
VOLTAGE TRANSFORMER UP TO 13.2 kV. |
|
Guide of selection up to13,2 kV. |
|
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer. |
|
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities. |
|
Voltage transformers Indoors Type up 13.2kV. |
Rango de
aplic. (kV) |
Power until (VA) |
Class |
Voltage factor |
Fuse |
Model |
Data |
2.3/0.11 á 6.6/0.11 |
60 |
0.5 |
1,2xUn |
No |
MV6-U |
View Details |
2.3/0.11 á 13.2/0.11
|
100
|
0.5
|
1,2xUn
|
Yes
|
MV3-BF |
|
2.3/0.11 á 13.2/0.11
|
100
|
0.5
|
1,2xUn
|
No
|
MV3 |
|
2.3/0.11 á 13.2/0.11
V3 V3 V3 V3 |
60
|
0.5
|
1,2xUn
|
Yes
|
MV3-UF |
|
2.3/0.11 á 13.2/0.11
V3 V3 V3 V3 |
60
|
0.5
|
1,2xUn
|
No
|
MV6-U |
|
2.3/0.11 á 13.2/0.11
V3 V3 V3 V3 |
100
|
0.5
|
1,2xUn
|
Yes
|
MV3 |
|
2.3/0.11 á 13.2/0.11
V3 V3 V3 V3 |
100
|
0.5
|
1,2xUn
|
No
|
MV3 |
|
|
|
NOTE: The transforming can offer with bases without projections also respecting the measures limited in the planes. |
|
|
|
|
VOLTAGE TRANSFORMER UP TO 33 kV. |
|
Guide of selection up to 33 kV. |
|
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer. |
|
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities. |
|
Voltage transformers Indoors Type up 33kV. |
Rango de
aplic. (kV) |
Power until (VA) |
Class |
Voltage factor |
Fuse |
Model |
Data |
33/0.11 |
100 |
0.5 |
1,2xUn |
No |
MV35 |
|
33/0.11
V3 . V3 |
100 |
0.5 |
1,2xUn |
Yes |
MV35 |
|
33/0.11
V3 . V3 |
100 |
0.5 |
1,2xUn |
No |
MV35 |
|
33 / 0.11 0.11
V3 . V3 - V3 |
30/60 |
0,2/3P - 0,5/3P |
1,2xUn |
No |
MV35 |
View Details |
|
|
NOTE: The transforming can offer with bases without projections also respecting the measures limited in the planes. |
|